Cabinet
Showing 1–12 of 34 resultsSorted by latest
-
DT320 … / DT321 …Over-voltage protector
- Transient voltage protection of 4-20 mA current loops
- 3-stage protection
- 10 kA surge (8 / 20 μs) withstand capability
- 41 V max. output voltage
- TS-35 rail mounting, 25 mm width
- IP 65 enclosure versions
More details
-
DT1300 Intrinsically Safe Isolator / Power Supply
- 0-20 mA / 4-20 mA / 0-10 V inputs
- 0-20 mA / 4-20 mA / 0-10 V outputs
- 17 VDC / 18 VDC transmitter supply
- Non-linearity < 0.01%
- Temperature-coefficient < 50 ppm / °C
- 19-29 VDC supply voltage
- TS-35 rail mounting, 12.5 mm width
- 18 different types
More details
-
DT1315 Intrinsically Safe Isolator / Power Supply
- 0-20 mA / 4-20 mA / 0-10 V inputs
- 0-20 mA / 4-20 mA / 0-10 V outputs
- Non-linearity < 0.01%
- Temperature-coefficient < 50 ppm / °C
- 19-29 VDC supply voltage
- TS-35 rail mounting, 12.5 mm width
- 9 different types
More details
-
DT1000 I4 Temperature Transmitter
- Pt 100 input
- 3 or 4 wire measurement
- -200 – +600 °C measurement ranges
- Two wire 4-20 mA transmitter
- 0.2 °C accuracy
- 875 uA measuring current
- TS-35 rail mounting, 12.5 mm width
More details
-
DT1005 I4 Resistance / Potentiometer Transmitter
- Resistance / potentiometer inputs
- 3 or 4 wire measurement
- 0-10000 ohm measurement ranges
- Two wire 4-20 mA transmitter
- 0.05% accuracy
- TS-35 rail mounting, 12.5 mm width
More details
-
DT1012 Temperature / Resistance / Potentiometer Transmitter
- Pt100 / Pt1000 sensors or resistance / potentiometer
can be connected to the input - 2 / 3 / 4 wire measurement
- -200 – +800 °C / 0-4000 ohm max. measurement ranges
- 0-20 mA / 4-20 mA current and
0-10 V / 2-10 V voltage output ranges - 3 way isolation (input / output / power supply)
- High precision measurement
- Easy configuration via USB port
- 24 VDC ±10% or 230 V AC/DC ±10% supply voltage
- DIN rail housing, width: 12.5 mm
More details
- Pt100 / Pt1000 sensors or resistance / potentiometer
-
DT1012 IP Temperature / Resistance / Potentiometer Transmitter
- Pt100 / Pt1000 sensors or resistance / potentiometer can be connected to the input
- 2 / 3 / 4 wire measurement
- -200 – +800 °C / 0-4000 ohm max. measurement ranges
- 4-20 mA passive current output
- 3 way isolation (input / output / power supply)
- High precision measurement
- Easy configuration via USB port
- 24 VDC ±10% or 230 V AC/DC ±10% supply voltage
- DIN rail housing, width: 12.5 mm
More details
-
DT1022 Temperature / potentiometer / resistance transmitters
- the input can be:
Pt100, Pt1000 sensors (-200 – +800 °C max.)
E, J, K, N, R, S, T thermocouples (-200 – +1768 °C max.)
linear resistance / potentiometer sensors (0 – 5000 ohms)
direct voltage (-100 mV – +100 mV) - the output can be:
0 – 20 mA / 4 – 20 mA current or
0 – 5 V / 0 – 10 V / 2 – 10 V voltage - 3 way isolation (input / outputs / power supply)
- high precision measurement characteristics
- easy configured via USB port
- 24 VDC ±10% or 230 V AC/DC ±10% supply voltage
- DIN rail housing, width 12.5 mm
More details
- the input can be:
-
DT1310 Intrinsically Safe Temperature / Resistance Transmitter
- Pt100 / Pt500 / Pt1000 inputs
- Resistance / potentiometer inputs
- 2 / 3 / 4 wire measurement
- -200 – +800 °C / 0-4000 ohm input ranges
- 0-20 mA / 4-20 mA / 0-10 V / 2-10 V output ranges
- 0.03% accuracy
- Easy configuration via IR transmission
- 19-35 VDC supply voltage
- TS-35 rail mounting, 12.5 mm width
More details
-
DT1361 Intrinsically Safe NAMUR / CONTACT Isolator
- NAMUR / contact inputs
- Relay contact / transistor outputs
- 1 channel version
- Line fault detection
- Switch selectable mode of operation
- 3 kHz transmission frequency (transistor output)
- 19-29 VDC supply voltage
- TS-35 rail mounting, 17.5 mm width devices
More details
-
DT1600 I AC Current Transmitter
- 0-1 AAC / 0-5 AAC measurement ranges
- Average values / True RMS values
- Galvanic isolated inputs, CAT III
- 0.2% accuracy
- 0-20 mA / 4-20 mA / 0-10 V outputs
- 24 VDC ±10% or 230 V AC/DC ±10% power supply
- TS-35 rail mounting, 22.5 mm width
- Full EN 60688 compliance
More details
-
DT1600 U AC Voltage Transmitter
- 0-125 VAC / 0-250 VAC / 0-450 VAC measurement ranges
- Average values / True RMS values
- Galvanic isolated inputs, CAT III
- 0.2% accuracy
- 0-20 mA / 4-20 mA / 0-10 V outputs
- 24 VDC ±10% or 230 V AC/DC ±10% power supply
- TS-35 rail mounting, 22.5 mm width
- Full EN 60688 compliance
More details
Showing 1–12 of 34 resultsSorted by latest