Process indicators
Showing all 11 resultsSorted by latest
-
DT420 E Process Indicator
- Display in engineering units
- 4-20 mA loop-powered
- 3 1/2 digit LCD display
- 15.2 mm character height
- Easy on site configuration
- IP 65 (front) and IP 30 (rear) protection

More details
-
DT4200 Process Indicator
- Display in engineering units
- 4-20 mA loop-powered
- 4 1/2 digit LCD display
- 15.2 mm character height
- Min. / Max. values detection 2 isolated limit outputs
- Easy on site configuration
- IP 65 (front) and IP 30 (rear) protection

More details
-
DT9000 Intrinsically Safe Process Indicator
- Display in engineering units
- 4 1/2 digit LCD, 20.5 mm character height
- 4-20 mA loop powered
- Min. / Max. values detection
- 2 isolated limit outputs
- 0.03% accuracy, ±20 ppm / °C
- Intrinsically safe (zone 1, 2)
- Easy on-site configuration
- IP 65

More details
-
DT9000 N Process Indicator
- Display in engineering units
- 4 1/2 digit LCD, 20.5 mm character height
- 4-20 mA loop powered
- Min. / Max. values detection
- 2 isolated limit outputs
- 0.03% accuracy, ±20 ppm / °C
- Easy on-site configuration
- DT9000: IP 65

More details
-
DT9002 Intrinsically Safe Process Indicator
- Display in engineering units
- 4 1/2 digit LCD, 20.5 mm character height
- 4-20 mA loop powered
- Min. / Max. values detection
- 2 isolated limit outputs
- 0.03% accuracy, ±20 ppm / °C
- Intrinsically safe (zone 1, 2)
- Easy on-site configuration
- IP 65 front IP 30 rear

More details
-
DT9002 N Process Indicator
- Display in engineering units
- 4 1/2 digit LCD, 20.5 mm character height
- 4-20 mA loop powered
- Min. / Max. values detection
- 2 isolated limit outputs
- 0.03% accuracy, ±20 ppm / °C
- Easy on-site configuration
- DT9002: IP 65 front, IP 30 rear

More details
-
DT4220 Process Indicator
- 0-20 mA / 4-20 mA / 0-10 V / 2-10 V / 0-5 V inputs
- 5 digit LED display, 14.2 mm character height colors: red, yellow, green, blue (optional)
- 0.03% accurary
- 0-20 mA / 4-20 mA, galvanic isolated output (optional)
- 2 limit relay output (optional)
- RS232 / RS485 communication, Modbus RTU protocol (optional)
- 96 × 48 mm panel instrument
- 24 VDC ±10% or 230 V AC/DC ±10% power supply
- Protection IP65 (front), IP30 (rear)

More details
-
DT4222 Process Indicator
- 0-20 mA / 4-20 mA / 0-10 V / 2-10 V / 0-5 V inputs
- 5 digit LED display, 20.3 mm character height
- 0.03% accuracy
- 0-20 mA / 4-20 mA, galvanic isolated output (optional)
- 2 limit relay outputs (optional)
- RS232 / RS485 communication, MODBUS RTU protocol (optional)
- 144 × 72 mm panel instrument
- 24 VDC ±10% or 230 V AC/DC ±10% power supply
- IP 65 (front) and IP 30 (rear) protection

More details
-
DT4226 Process Indicator
- 0-20 mA / 4-20 mA / 0-10 V / 2-10 V / 0-5 V inputs
- large, 5 digit LED display (101 mm character height)
- adjustable brightness
- readable even at a 50 m distance
- menu driven setting, via front panel switches
- 0.03% accuracy
- 24 VDC ±10% or 230 V AC/DC ±10% power supply
- 656 × 150 × 45 mm wall mount instrument

More details
-
DT4227 Process Indicator
- 0-20 mA / 4-20 mA / 0-10 V / 2-10 V / 0-5 V inputs
- large, 5 digit LED display (57 mm character height)
- 0.03% accuracy
- 0-20 mA / 4-20 mA, galvanic isolated output (optional)
- 2 limit relay output (optional)
- RS232 / RS485 communication, Modbus RTU protocol (optional)
- 24 VDC ±10% or 230 V AC/DC ±10% power supply
- 288 × 96 mm panel instrument
- Protection IP 52 (front), IP 20 (rear)

More details
-
DT9222 Process Indicator
- 0-20 mA / 4-20 mA / 0-10 V / 2-10 V / 0-5 V inputs
- 5 digit LED display, 20.3 mm character height
- 0.03% accuracy
- 0-20 mA / 4-20 mA, galvanic isolated output (optional)
- 2 limit relay output (optional)
- RS232 / RS485 communication, MODBUS RTU protocol (optional)
- 24 VDC ±10% or
230 V AC/DC ±10% power supply - IP 65 protection
- readable even at a 10 m distance

More details
Showing all 11 resultsSorted by latest