Temperature / resistance potentiometer meters, transmitters
Showing all 10 resultsSorted by latest
-
DT1000 I4 Temperature Transmitter
- Pt 100 input
- 3 or 4 wire measurement
- -200 – +600 °C measurement ranges
- Two wire 4-20 mA transmitter
- 0.2 °C accuracy
- 875 uA measuring current
- TS-35 rail mounting, 12.5 mm width
More details
-
DT1005 I4 Resistance / Potentiometer Transmitter
- Resistance / potentiometer inputs
- 3 or 4 wire measurement
- 0-10000 ohm measurement ranges
- Two wire 4-20 mA transmitter
- 0.05% accuracy
- TS-35 rail mounting, 12.5 mm width
More details
-
DT1012 Temperature / Resistance / Potentiometer Transmitter
- Pt100 / Pt1000 sensors or resistance / potentiometer
can be connected to the input - 2 / 3 / 4 wire measurement
- -200 – +800 °C / 0-4000 ohm max. measurement ranges
- 0-20 mA / 4-20 mA current and
0-10 V / 2-10 V voltage output ranges - 3 way isolation (input / output / power supply)
- High precision measurement
- Easy configuration via USB port
- 24 VDC ±10% or 230 V AC/DC ±10% supply voltage
- DIN rail housing, width: 12.5 mm
More details
- Pt100 / Pt1000 sensors or resistance / potentiometer
-
DT1012 IP Temperature / Resistance / Potentiometer Transmitter
- Pt100 / Pt1000 sensors or resistance / potentiometer can be connected to the input
- 2 / 3 / 4 wire measurement
- -200 – +800 °C / 0-4000 ohm max. measurement ranges
- 4-20 mA passive current output
- 3 way isolation (input / output / power supply)
- High precision measurement
- Easy configuration via USB port
- 24 VDC ±10% or 230 V AC/DC ±10% supply voltage
- DIN rail housing, width: 12.5 mm
More details
-
DT1022 Temperature / potentiometer / resistance transmitters
- the input can be:
Pt100, Pt1000 sensors (-200 – +800 °C max.)
E, J, K, N, R, S, T thermocouples (-200 – +1768 °C max.)
linear resistance / potentiometer sensors (0 – 5000 ohms)
direct voltage (-100 mV – +100 mV) - the output can be:
0 – 20 mA / 4 – 20 mA current or
0 – 5 V / 0 – 10 V / 2 – 10 V voltage - 3 way isolation (input / outputs / power supply)
- high precision measurement characteristics
- easy configured via USB port
- 24 VDC ±10% or 230 V AC/DC ±10% supply voltage
- DIN rail housing, width 12.5 mm
More details
- the input can be:
-
DT1310 Intrinsically Safe Temperature / Resistance Transmitter
- Pt100 / Pt500 / Pt1000 inputs
- Resistance / potentiometer inputs
- 2 / 3 / 4 wire measurement
- -200 – +800 °C / 0-4000 ohm input ranges
- 0-20 mA / 4-20 mA / 0-10 V / 2-10 V output ranges
- 0.03% accuracy
- Easy configuration via IR transmission
- 19-35 VDC supply voltage
- TS-35 rail mounting, 12.5 mm width
More details
-
DT4120 Resistance Thermometer
- Pt100 / Pt500 / Pt1000, resistance / potentiometer inputs
- 2 / 3 / 4 wire measurement
- 5 digit LED display, 14.2 mm character height
- 0.1 °C resolution
- 0-20 mA / 4-20 mA, galvanic isolated output (optional)
- 2 limit relay outputs (optional)
- RS232 / RS485 communication, MODBUS RTU protocol (optional)
- 96 × 48 mm panel instrument, < 50 mm built-in depth
- 24 VDC ±10%, 230 V AC/DC ±10% power supply
- IP 65 (front) and IP 30 (rear) protection
More details
-
DT4122 Resistance Thermometer
- Pt100 / Pt500 / Pt1000, resistance / potentiometer inputs
- 2 / 3 / 4 wire measurement
- 5 digit LED display, 20.3 mm character height
- 0.1 °C resolution
- 0-20 mA / 4-20 mA, galvanic isolated output (optional)
- 2 limit relay outputs (optional)
- RS232 / RS485 communication, MODBUS RTU protocol (optional)
- 144 × 72 mm panel instrument
- 24 VDC ±10% or, 230 V AC/DC ±10% power supply
- IP 65 (front) and IP 30 (rear) protection
More details
-
DT9500 Intrinsically Safe Resistance Thermometer / Transmitter
- Pt100 input, 3 / 4 wire measurement
- -200 – +600 °C measuring range
- 0.3 °C accuracy
- 4-20 mA loop powered
- Easy on-site configuration
- Calibrated sensor curve fitting
- 2 isolated limit outputs
- Min. / Max. values detection
- 4 1/2 digit LCD, 20.5 mm character height
- Intrinsically safe (zone 1, 2)
- IP 65
More details
-
DT9502 Intrinsically Safe Resistance Thermometer / Transmitter
- Pt100 input, 3 / 4 wire measurement
- -200 – +600 °C measuring range
- 0.3 °C accuracy
- 4-20 mA loop powered
- Easy on-site configuration
- Calibrated sensor curve fitting
- 2 isolated limit outputs
- Min. / Max. values detection
- 4 1/2 digit LCD, 20.5 mm character height
- Intrinsically safe (zone 1, 2)
- IP 65 front, IP 30 rear
More details
Showing all 10 resultsSorted by latest